Nireos Hera Iperspettrale VIS-NIR

Nireos Hera Iperspettrale VIS-NIR

Spectral range = 400 – 1000 nm
Sensor spatial resolution = 1280 x 1024 pixels
User adjustable spectral resolution: <1.5 nm @ 400 nm/ <10 nm @ 1000 nm Sensor = CMOS Number of bits = 12 bits Software interface = Labview based interface Number of spectral bands = ?* Field of view 8 degrees** Working distance = 1 m - ? Dimensions = 205 x 150 x 83.5 mm Weight = 2 kg * HERA is FT spectroscopy based instrument and number of spectral bands is software selectable and independent from measurement time ** The Field of View can be doubled (up to 16 degrees) by adding an optional lens in front of the camera

SKU: Nireos Hera Iperspettrale VIS-NIR Category: Tag:
Compare

HERA IPERSPETTRALE is a compact and rugged camera that enables an innovative approach to spectral imaging.
With its unique and patented technology based on time-domain Fourier Transform (FT) detection, HERA provides exceptional spatial-spectral resolution and superior sensitivity in low-light illumination conditions.
HERA is based on a Fourier Transform (FT) approach: the data-cube is acquired in the time-domain, by step-scanning a compact ultra-stable interferometer in front of the CMOS sensor.
The software then automatically computes an FT at each and every pixel of the image, providing the final hyperspectral data-cube.
As a result of an FT, the spectrum at each pixel is a continuous curve, so the number of bands is virtually unlimited, not defined by the hardware.
As in any other FT techniques, the spectral resolution is not constant as a function of the wavelength. Also, the spectral resolution can be simply varied via software: at each measurement, you can decide whether to acquire a high spectral resolution-image, or – if not required – a faster and lower spectral resolution-image.
Regardless of this choice, the exceptional light throughput is not affected, thanks to the FT approach.
Thanks to the absence of aperture slits and gratings, and to the 1 cm Clear Aperture, HERA is specifically designed to provide an extremely high light throughput, making it the ideal device for low light conditions or delicate samples.

Leave a Reply

Your email address will not be published. Required fields are marked *

Got something to discuss?


 

Quick Comparison

Nireos Hera Iperspettrale VIS-NIR removeHySpex Mjolnir S-620 removeHySpex Mjolnir V-1240 removeHySpex Baldur V-1024 N removeHySpex SWIR-384 removeSpecim Fenix remove
NameNireos Hera Iperspettrale VIS-NIR removeHySpex Mjolnir S-620 removeHySpex Mjolnir V-1240 removeHySpex Baldur V-1024 N removeHySpex SWIR-384 removeSpecim Fenix remove
ImageNireos Hera Iperspettrale VIS-NIRHySpex Mjolnir S-620HySpex Mjolnir V-1240HySpex Baldur V-1024 NHySpex SWIR-384Specim Fenix
Rating
Rated 0 out of 5
Rated 0 out of 5
Rated 0 out of 5
Rated 0 out of 5
Rated 4.67 out of 5
Rated 0 out of 5
ContentHERA IPERSPETTRALE is a compact and rugged camera that enables an innovative approach to spectral imaging. With its unique and patented technology based on time-domain Fourier Transform (FT) detection, HERA provides exceptional spatial-spectral resolution and superior sensitivity in low-light illumination conditions. HERA is based on a Fourier Transform (FT) approach: the data-cube is acquired in the time-domain, by step-scanning a compact ultra-stable interferometer in front of the CMOS sensor. The software then automatically computes an FT at each and every pixel of the image, providing the final hyperspectral data-cube. As a result of an FT, the spectrum at each pixel is a continuous curve, so the number of bands is virtually unlimited, not defined by the hardware. As in any other FT techniques, the spectral resolution is not constant as a function of the wavelength. Also, the spectral resolution can be simply varied via software: at each measurement, you can decide whether to acquire a high spectral resolution-image, or - if not required - a faster and lower spectral resolution-image. Regardless of this choice, the exceptional light throughput is not affected, thanks to the FT approach. Thanks to the absence of aperture slits and gratings, and to the 1 cm Clear Aperture, HERA is specifically designed to provide an extremely high light throughput, making it the ideal device for low light conditions or delicate samples.HySpex Mjolnir S-620 The HySpex Mjolnir S-620 hyperspectral imaging system for UAVs is the SWIR version of the Mjolnir camera series. Similar to the VNIR version, it provides a unique combination of small form factor and low mass, combined with high-performance specifications and scientific grade data quality. With a weight of less than 4.5 kg and less than 50 W power consumption, HySpex Mjolnir S-620 is very well suited for a wide range of UAVs. NEO offers high-performance unmanned aerial vehicles, fully integrated with the HySpex Mjolnir S-620. The UAV is fitted with a standard battery package allowing up to 30 minutes of flight time. All HySpex Mjolnir systems can also be mounted on a tripod and rotation stage for ground use.HySpex Mjolnir V-1240 The HySpex Mjolnir V-1240 hyperspectral imaging system for UAVs provides a unique combination of small form factor and low mass, combined with high-performance specifications and scientific grade data quality. With a weight of less than 4 kg and less than 50 W power consumption, HySpex Mjolnir V-1240 is very well suited for a wide range of UAVs. The system is also compatible with several off-the-shelf gimbals. NEO offers high-performance unmanned aerial vehicles, fully integrated with the HySpex Mjolnir V-1240. The UAV is fitted with a standard battery package allowing up to 30 minutes of flight time. All HySpex Mjolnir systems can also be mounted on a tripod and rotation stage for ground use.HySpex Baldur V-1024 N Baldur V-1024 N covers the full VNIR spectral range from 400-1000nm and is configurable within one octave in the same range. All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur V-1024 N is better than 1.7 pixels, yielding a very sharp camera.HySpex SWIR-384 The HySpex SWIR-384 hyperspectral camera is developed for field, laboratory, and airborne applications. The state of the art MCT sensor with cooling down to 150K yields low background noise, high dynamic range, and exceptional SNR levels. With a max frame rate of 400 fps, combined with an aberration-corrected optical system with high optical throughput (f/2), the data quality, speed, and sensitivity is truly state of the art. A wide range of close-up lenses allows the use of the camera at working distances ranging from a few centimeters with a spatial resolution of 53 ?m to infinity e.g. airborne remote sensing.Fenix FENIX is optimized for the most demanding geological, law enforcement, and environmental applications. In a single continuous image, FENIX spectral camera delivers the best hyperspectral data ever seen over VNIR, NIR, and SWIR wavelengths. FENIX offers extreme ruggedness and 75% reduction in size and weight compared to previous multi-sensor systems. The excellence in technical performance and physical size has been achieved through innovative and unique ?single optics dual spectrograph? design.
DescriptionSpectral range = 400 - 1000 nm Sensor spatial resolution = 1280 x 1024 pixels User adjustable spectral resolution: <1.5 nm @ 400 nm/ <10 nm @ 1000 nm Sensor = CMOS Number of bits = 12 bits Software interface = Labview based interface Number of spectral bands = ?* Field of view 8 degrees** Working distance = 1 m - ? Dimensions = 205 x 150 x 83.5 mm Weight = 2 kg * HERA is FT spectroscopy based instrument and number of spectral bands is software selectable and independent from measurement time ** The Field of View can be doubled (up to 16 degrees) by adding an optional lens in front of the cameraSpectral range = 970 - 2500 nm Spatial pixels = 620 Spectral channels and sampling = 300 bands @ 5.1 nm F-number = F1.9 FOV = 20? Pixel FOV across/along = 0.54/0.54 mrad Bit resolution = 16 bit Noise floor = 80 e- Dynamic range = 10000 Peak SNR (at full resolution) > 900 Max speed (at full resolution) = 170 fps Power consumption* = 50 W Dimensions (l-w-h)* = 254 - 175 - 170 mm Weight* < 4.5 kg *Includes IMU/GPS and DAU - <5 kg including standard batterySpectral range = 400 - 1000 nm Spatial pixels = 1240 Spectral channels and sampling = 200 bands @ 3 nm F-number = F1.8 FOV = 20? Pixel FOV across/along = 0.27/0.27 mrad Bit resolution = 12 bit Noise floor = 2.3 e- Dynamic range = 4400 Peak SNR (at full resolution) > 180 Max speed (at full resolution) = 285 fps Power consumption = 50 W Dimensions (l-w-h) = 250 - 175 - 170 mm Weight < 4 kg *Includes IMU/GPS and DAU - <6.5 kg including standard batterySpectral Range = 400-800/485-960/400-1000 nm Spatial pixels = 1024 Spectral bands = 72/88/106 Max speed* = 1000/800/700 fps Spectral sampling = 5.5 nm Spectral FWHM <2 bands? Spatial FWHM < 1.7 pixels Keystone <15% of a pixel Smile <15% of band FOV = 16? / 40? Bit resolution = 12 Noise floor = 11e Peak SNR >286 Dynamic range = 2560 ROI* = 8 independent ROIs Dimensions (l-w-h) = 316 - 105 - 153 mm Camera Interface = CameraLink * Reducing the number of spectral channels with ROI will proportionally increase the max framerateSpectral range = 930 - 2500 nm Spatial pixels = 384 Spectral channels = 288 Spectral sampling = 5.45 nm FOV* = 16? Pixel FOV across/along* = 0.73/0.73 mrad Bit resolution = 16 bit Noise floor = 150 e- Dynamic range = 7500 Peak SNR (at full resolution) > 1100 Max speed (at full resolution) = 400 fps Power consumption = 30 W Dimensions (l-w-h) = 38 - 12- 17.5 cm Weight = 5.7 kg Camera Interface = CameraLink *Can be doubled with FOV expander
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Content
  • Description
Click outside to hide the comparison bar
Compare
Compare ×
Let's Compare! Continue shopping
Scroll to Top