HERA IPERSPETTRALE is a compact and rugged camera that enables an innovative approach to spectral imaging.
With its unique and patented technology based on time-domain Fourier Transform (FT) detection, HERA provides exceptional spatial-spectral resolution and superior sensitivity in low-light illumination conditions.
HERA is based on a Fourier Transform (FT) approach: the data-cube is acquired in the time-domain, by step-scanning a compact ultra-stable interferometer in front of the CMOS sensor.
The software then automatically computes an FT at each and every pixel of the image, providing the final hyperspectral data-cube.
As a result of an FT, the spectrum at each pixel is a continuous curve, so the number of bands is virtually unlimited, not defined by the hardware.
As in any other FT techniques, the spectral resolution is not constant as a function of the wavelength. Also, the spectral resolution can be simply varied via software: at each measurement, you can decide whether to acquire a high spectral resolution-image, or – if not required – a faster and lower spectral resolution-image.
Regardless of this choice, the exceptional light throughput is not affected, thanks to the FT approach.
Thanks to the absence of aperture slits and gratings, and to the 1 cm Clear Aperture, HERA is specifically designed to provide an extremely high light throughput, making it the ideal device for low light conditions or delicate samples.
Nireos Hera Iperspettrale VIS-NIR
VNIR-SWIR Compare
Nireos Hera Iperspettrale VIS-NIR
Spectral range = 400 – 1000 nm
Sensor spatial resolution = 1280 x 1024 pixels
User adjustable spectral resolution: <1.5 nm @ 400 nm/ <10 nm @ 1000 nm
Sensor = CMOS
Number of bits = 12 bits
Software interface = Labview based interface
Number of spectral bands = ?*
Field of view 8 degrees**
Working distance = 1 m - ?
Dimensions = 205 x 150 x 83.5 mm
Weight = 2 kg * HERA is FT spectroscopy based instrument and number of spectral bands is software selectable and independent from measurement time
** The Field of View can be doubled (up to 16 degrees) by adding an optional lens in front of the camera
Quick Comparison
Nireos Hera Iperspettrale VIS-NIR remove | Specim FX10 remove | Resonon Pika IR-L remove | Resonon Pika L remove | HySpex Baldur S-384 N remove | Specim Fenix remove | |
---|---|---|---|---|---|---|
Name | Nireos Hera Iperspettrale VIS-NIR remove | Specim FX10 remove | Resonon Pika IR-L remove | Resonon Pika L remove | HySpex Baldur S-384 N remove | Specim Fenix remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
Rating | ||||||
Content | HERA IPERSPETTRALE is a compact and rugged camera that enables an innovative approach to spectral imaging. With its unique and patented technology based on time-domain Fourier Transform (FT) detection, HERA provides exceptional spatial-spectral resolution and superior sensitivity in low-light illumination conditions. HERA is based on a Fourier Transform (FT) approach: the data-cube is acquired in the time-domain, by step-scanning a compact ultra-stable interferometer in front of the CMOS sensor. The software then automatically computes an FT at each and every pixel of the image, providing the final hyperspectral data-cube. As a result of an FT, the spectrum at each pixel is a continuous curve, so the number of bands is virtually unlimited, not defined by the hardware. As in any other FT techniques, the spectral resolution is not constant as a function of the wavelength. Also, the spectral resolution can be simply varied via software: at each measurement, you can decide whether to acquire a high spectral resolution-image, or - if not required - a faster and lower spectral resolution-image. Regardless of this choice, the exceptional light throughput is not affected, thanks to the FT approach. Thanks to the absence of aperture slits and gratings, and to the 1 cm Clear Aperture, HERA is specifically designed to provide an extremely high light throughput, making it the ideal device for low light conditions or delicate samples. | Specim FX10 Specim FX10 is a line-scan hyperspectral camera that operates in the visible and near-infrared (VNIR) region. It is an excellent tool for industrial and scientific applications. The Specim FX10 operates in the 400-1000 nm region, and the color-optimized Specim FX10c in the 400-780 nm region. | Pika IR-L 925 - 1700 nm Lightweight Infrared The Pika IR-L is a lightweight and compact Near-Infrared (925-1,700 nm) imager. The small size and mass make it well suited for airborne applications, where it can provide invisible to the naked-eye contrast of outdoor features. For a compact, lightweight Visible light spectral range option, please see the Pika L. For a higher spectral and spatial resolution version of the Pika IR-L, please see the Pika IR-L+ imager. | Pika L 400 - 1000 nm Lightweight, Compact VNIR The Pika L is a lightweight, compact hyperspectral camera that covers the Visible + Near-Infrared (VNIR) spectral range. It is our most popular imager for remote sensing applications. The Pika L can be used in our airborne, laboratory, and outdoor hyperspectral systems, as well as standalone or integrated into your system. | HySpex Baldur S-384 N Baldur S-384 N covers the spectral range from 960-2500 nm. All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur S-384 N is better than 1.5 pixels, yielding a very sharp camera. | Fenix FENIX is optimized for the most demanding geological, law enforcement, and environmental applications. In a single continuous image, FENIX spectral camera delivers the best hyperspectral data ever seen over VNIR, NIR, and SWIR wavelengths. FENIX offers extreme ruggedness and 75% reduction in size and weight compared to previous multi-sensor systems. The excellence in technical performance and physical size has been achieved through innovative and unique ?single optics dual spectrograph? design. |
Description | Spectral range = 400 - 1000 nm Sensor spatial resolution = 1280 x 1024 pixels User adjustable spectral resolution: <1.5 nm @ 400 nm/ <10 nm @ 1000 nm Sensor = CMOS Number of bits = 12 bits Software interface = Labview based interface Number of spectral bands = ?* Field of view 8 degrees** Working distance = 1 m - ? Dimensions = 205 x 150 x 83.5 mm Weight = 2 kg * HERA is FT spectroscopy based instrument and number of spectral bands is software selectable and independent from measurement time ** The Field of View can be doubled (up to 16 degrees) by adding an optional lens in front of the camera | Spectral Range = 400-1000 / 400-780 (c-version) Spectral resolution (FWHM) = 5.5 nm (mean) Spectral sampling/pixel = 2.7 nm, With default binning Spectral bands = 224 / 140 (c-version), With default binning Numerical aperture = 1.7, With default lens Optics magnification = 0.80 Effective pixel size = 19.9x9.97 ?m, At fore lens image plane Effective slit width = 42 ?m, At fore lens image plane Effective slit length = 10.2 mm, At fore lens image plane SNR @ max. signal = 420 : 1 Spatial samples = 1024 Bit depth = 12 Maximum frame rate = 327 FPS full range / 514 FPS full range (c-version) Binning = 2,4,8 spectral and spatial Default: 2 spectral x 1 spatial ROI = Freely selectable multiple bands of interest. Minimum height of ROI is two 1-binned rows. Maximum frame rate is determined by the total number of rows included in the mMROI?s Pixel operability = 99.993% Image corrections = Non uniformity correction/Bad pixel replacement/Automatic Image Enhancement (AIE)/One point NUC. AIE: Unified spectral calibration + corrected smile and keystone aberrations Sensor material = CMOS Sensor cooling = Passive Full well capacity = 90 ke- Read-out modes = IWR / ITR Optics temperature = Passive Lens mount = Custom mount Fore lens FOV options = 12 deg/ 38 deg (default)/ 47 deg/ 51 deg/ 83 deg. Only the default lens is specifically designed for FX10. With other lens options, optical parameters may vary. Camera digital data output/control interface = GigE Vision, CameraLink Camera control protocols = GenICam, ASCII Power input = 12 V DC (+-10%) Power consumption = Max 4 W Connectors = Industrial Ethernet OR CameraLink 26-pin, 0.5? MDR IP = IP52 Dimensions (L x W x H) = 150 x 85 x 71 mm Mounting surface option on three sides. Mounting kit adds 24 mm distance on mounting side. Weight = 1.3 kg Storage temperature = -20 ... +50?C (non-condensing) Operating temperature = +5 ? +40?C (non-condensing) Relative humidity = 5% - 95% (non-condensing) | Spectral Range (nm) = 925 - 1700 Spectral Channels = 236 Spectral Bandwidth (nm) = 3.3 Spectral Resolution - FWHM (nm) = 5.9 Spatial Pixels = 320 Max Frame Rate (fps) = 364 f/# = 1.8 Interface = GigE Dimensions (mm) = 210 x 68 x 63 Weight, w/o lens (kg) = 1.01 | Spectral Range (nm) = 400 - 1000 Spectral Channels = 281 Spectral Bandwidth (nm) = 2.1 Spectral Resolution - FWHM (nm) = 3.3 Spatial Pixels = 900 Max Frame Rate (fps) = 249 f/# = 2.4 Interface = USB 3.0 Dimensions (mm) = 115 x 104 x 66 Weight, w/o lens (kg) = 0.64 | Spectral Range = 960 - 2500nm Spectral bands = 288 Max speed* = 500 fps Spectral sampling = 5.45 nm Spectral FWHM <2 bands Spatial FWHM <1.3 pixels Spatial pixels = 384 Keystone <15% of a pixel Smile <15% of band FOV = 16? / 40? Bit resolution = 16 bit Noise floor = 150 e- Peak SNR >1100 Dynamic range = 7500 ROI* = All bands can be selected/deselected individually External trigger options LVDS, 5V/12V/24V TTL Dimensions (l-w-h) = 368 - 131 - 175 mm Camera Interface = CameraLink * Reducing the number of spectral channels with ROI will proportionally increase the max framerate |
Leave a Reply