Headwall Hyperspec Co-Aligned HP VNIR-SWIR

Headwall Hyperspec Co-Aligned HP VNIR-SWIR

SKU: Headwall Hyperspec Co-Aligned HP VNIR-SWIR Category: Tag:
Compare

NEW Hyperspec? Co-Aligned HP VNIR-SWIR
Designed for airborne or ground-based hyperspectral imaging in the field, the Co-Aligned VNIR-SWIR HP sensor contains co-aligned VNIR (the NEW Nano HP?) and SWIR systems with independent optical and data-acquisition and solid-state storage, as well as a high-performance GPS/IMU. The field-of-view for each system is closely matched, and LiDAR can also be added.

Reviews

There are no reviews yet.

Be the first to review “Headwall Hyperspec Co-Aligned HP VNIR-SWIR”

Your email address will not be published. Required fields are marked *

Got something to discuss?


 

Quick Comparison

Headwall Hyperspec Co-Aligned HP VNIR-SWIR removeHySpex SWIR-384 removeSpecim Fenix removeHySpex Mjolnir S-620 removeResonon Pika XC2 removeHySpex Baldur V-1024 N remove
NameHeadwall Hyperspec Co-Aligned HP VNIR-SWIR removeHySpex SWIR-384 removeSpecim Fenix removeHySpex Mjolnir S-620 removeResonon Pika XC2 removeHySpex Baldur V-1024 N remove
Image
Rating
Rated 0 out of 5
Rated 4.67 out of 5
Rated 0 out of 5
Rated 0 out of 5
Rated 4.33 out of 5
Rated 0 out of 5
ContentNEW Hyperspec? Co-Aligned HP VNIR-SWIR Designed for airborne or ground-based hyperspectral imaging in the field, the Co-Aligned VNIR-SWIR HP sensor contains co-aligned VNIR (the NEW Nano HP?) and SWIR systems with independent optical and data-acquisition and solid-state storage, as well as a high-performance GPS/IMU. The field-of-view for each system is closely matched, and LiDAR can also be added.HySpex SWIR-384 The HySpex SWIR-384 hyperspectral camera is developed for field, laboratory, and airborne applications. The state of the art MCT sensor with cooling down to 150K yields low background noise, high dynamic range, and exceptional SNR levels. With a max frame rate of 400 fps, combined with an aberration-corrected optical system with high optical throughput (f/2), the data quality, speed, and sensitivity is truly state of the art. A wide range of close-up lenses allows the use of the camera at working distances ranging from a few centimeters with a spatial resolution of 53 ?m to infinity e.g. airborne remote sensing.Fenix FENIX is optimized for the most demanding geological, law enforcement, and environmental applications. In a single continuous image, FENIX spectral camera delivers the best hyperspectral data ever seen over VNIR, NIR, and SWIR wavelengths. FENIX offers extreme ruggedness and 75% reduction in size and weight compared to previous multi-sensor systems. The excellence in technical performance and physical size has been achieved through innovative and unique ?single optics dual spectrograph? design.HySpex Mjolnir S-620 The HySpex Mjolnir S-620 hyperspectral imaging system for UAVs is the SWIR version of the Mjolnir camera series. Similar to the VNIR version, it provides a unique combination of small form factor and low mass, combined with high-performance specifications and scientific grade data quality. With a weight of less than 4.5 kg and less than 50 W power consumption, HySpex Mjolnir S-620 is very well suited for a wide range of UAVs. NEO offers high-performance unmanned aerial vehicles, fully integrated with the HySpex Mjolnir S-620. The UAV is fitted with a standard battery package allowing up to 30 minutes of flight time. All HySpex Mjolnir systems can also be mounted on a tripod and rotation stage for ground use.Pika XC2 400 - 1000 nm High-Precision VNIR The Pika XC2 is a high-resolution hyperspectral camera that covers the Visible + Near-Infrared (VNIR) spectral range. The Pika XC2 has high spatial resolution, best in-class spectral resolution, and excellent imaging quality. Popular in VNIR laboratory applications. The Pika XC2 can be used in our laboratory, and outdoor, and airborne hyperspectral systems, as well as standalone or integrated into your system.HySpex Baldur V-1024 N Baldur V-1024 N covers the full VNIR spectral range from 400-1000nm and is configurable within one octave in the same range. All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur V-1024 N is better than 1.7 pixels, yielding a very sharp camera.
DescriptionSpectral range = 930 - 2500 nm Spatial pixels = 384 Spectral channels = 288 Spectral sampling = 5.45 nm FOV* = 16? Pixel FOV across/along* = 0.73/0.73 mrad Bit resolution = 16 bit Noise floor = 150 e- Dynamic range = 7500 Peak SNR (at full resolution) > 1100 Max speed (at full resolution) = 400 fps Power consumption = 30 W Dimensions (l-w-h) = 38 - 12- 17.5 cm Weight = 5.7 kg Camera Interface = CameraLink *Can be doubled with FOV expanderSpectral range = 970 - 2500 nm Spatial pixels = 620 Spectral channels and sampling = 300 bands @ 5.1 nm F-number = F1.9 FOV = 20? Pixel FOV across/along = 0.54/0.54 mrad Bit resolution = 16 bit Noise floor = 80 e- Dynamic range = 10000 Peak SNR (at full resolution) > 900 Max speed (at full resolution) = 170 fps Power consumption* = 50 W Dimensions (l-w-h)* = 254 - 175 - 170 mm Weight* < 4.5 kg *Includes IMU/GPS and DAU - <5 kg including standard batterySpectral Range (nm) = 400 - 1000 Spectral Channels = 447 Spectral Bandwidth (nm) = 1.3 Spectral Resolution - FWHM (nm) = 1.9 Spatial Pixels = 1600 Max Frame Rate (fps) = 165 f/# = 2.4 Interface = USB 3.0 Dimensions (mm) = 265 x 106 x 75 Weight, w/o lens (kg) = 2.51Spectral Range = 400-800/485-960/400-1000 nm Spatial pixels = 1024 Spectral bands = 72/88/106 Max speed* = 1000/800/700 fps Spectral sampling = 5.5 nm Spectral FWHM <2 bands? Spatial FWHM < 1.7 pixels Keystone <15% of a pixel Smile <15% of band FOV = 16? / 40? Bit resolution = 12 Noise floor = 11e Peak SNR >286 Dynamic range = 2560 ROI* = 8 independent ROIs Dimensions (l-w-h) = 316 - 105 - 153 mm Camera Interface = CameraLink * Reducing the number of spectral channels with ROI will proportionally increase the max framerate
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Content
  • Description
Click outside to hide the comparison bar
Compare
Compare ×
Let's Compare! Continue shopping
Scroll to Top