HERA IPERSPETTRALE is a compact and rugged camera that enables an innovative approach to spectral imaging.
With its unique and patented technology based on time-domain Fourier Transform (FT) detection, HERA provides exceptional spatial-spectral resolution and superior sensitivity in low-light illumination conditions.
HERA is based on a Fourier Transform (FT) approach: the data-cube is acquired in the time-domain, by step-scanning a compact ultra-stable interferometer in front of the bidimensional sensor.
The software then automatically computes an FT at each and every pixel of the image, providing the final hyperspectral data-cube.
As a result of an FT, the spectrum at each pixel is a continuous curve, so the number of bands is virtually unlimited, not defined by the hardware.
As in any other FT techniques, the spectral resolution is not constant as a function of the wavelength. Also, the spectral resolution can be simply varied via software: at each measurement, you can decide whether to acquire a high spectral resolution-image, or – if not required – a faster and lower spectral resolution-image.
Regardless of this choice, the exceptional light throughput is not affected, thanks to the FT approach.
Nireos Hera Iperspettrale Extended SWIR
SWIR Compare
Nireos Hera Iperspettrale Extended SWIR
Spectral range = 900 – 2300 nm
Sensor spatial resolution = 320 x 256 pixels
User adjustable spectral resolution: < 5 nm @ 900 nm/ <30 nm @ 2300 nm
Detector type = T2SL photodiode array with CTIA ROIC, 4-stage TE cooler
Number of bits = 14 bits
Software interface = Labview based interface
Number of spectral bands = ?*
Field of view 16 degrees
Working distance = 110 cm - ?
Dimensions = 240 x 170 x 120 mm
Weight = 5 kg
Minimum Computer Requirements = 16 GB RAM, SSD drive suggested * HERA is FT spectroscopy based instrument and number of spectral bands is software selectable and independent from measurement
Quick Comparison
Nireos Hera Iperspettrale Extended SWIR remove | Resonon Pika IR+ remove | Specim FX10 remove | HySpex SWIR-384 remove | Resonon Pika IR-L remove | Specim Fenix remove | |
---|---|---|---|---|---|---|
Name | Nireos Hera Iperspettrale Extended SWIR remove | Resonon Pika IR+ remove | Specim FX10 remove | HySpex SWIR-384 remove | Resonon Pika IR-L remove | Specim Fenix remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
Rating | ||||||
Content | HERA IPERSPETTRALE is a compact and rugged camera that enables an innovative approach to spectral imaging. With its unique and patented technology based on time-domain Fourier Transform (FT) detection, HERA provides exceptional spatial-spectral resolution and superior sensitivity in low-light illumination conditions. HERA is based on a Fourier Transform (FT) approach: the data-cube is acquired in the time-domain, by step-scanning a compact ultra-stable interferometer in front of the bidimensional sensor. The software then automatically computes an FT at each and every pixel of the image, providing the final hyperspectral data-cube. As a result of an FT, the spectrum at each pixel is a continuous curve, so the number of bands is virtually unlimited, not defined by the hardware. As in any other FT techniques, the spectral resolution is not constant as a function of the wavelength. Also, the spectral resolution can be simply varied via software: at each measurement, you can decide whether to acquire a high spectral resolution-image, or - if not required - a faster and lower spectral resolution-image. Regardless of this choice, the exceptional light throughput is not affected, thanks to the FT approach. | Pika IR+ 900 - 1700 nm High-Precision Infrared The Pika IR+ (formerly Pika NIR-640) is a high-performance hyperspectral camera that covers the Near-Infrared (NIR) spectral range. It has high spatial and spectral resolutions and is often used for infrared laboratory applications. The Pika IR+ can be used in our airborne, laboratory, and outdoor hyperspectral systems, as well as standalone or integrated into your system. | Specim FX10 Specim FX10 is a line-scan hyperspectral camera that operates in the visible and near-infrared (VNIR) region. It is an excellent tool for industrial and scientific applications. The Specim FX10 operates in the 400-1000 nm region, and the color-optimized Specim FX10c in the 400-780 nm region. | HySpex SWIR-384 The HySpex SWIR-384 hyperspectral camera is developed for field, laboratory, and airborne applications. The state of the art MCT sensor with cooling down to 150K yields low background noise, high dynamic range, and exceptional SNR levels. With a max frame rate of 400 fps, combined with an aberration-corrected optical system with high optical throughput (f/2), the data quality, speed, and sensitivity is truly state of the art. A wide range of close-up lenses allows the use of the camera at working distances ranging from a few centimeters with a spatial resolution of 53 ?m to infinity e.g. airborne remote sensing. | Pika IR-L 925 - 1700 nm Lightweight Infrared The Pika IR-L is a lightweight and compact Near-Infrared (925-1,700 nm) imager. The small size and mass make it well suited for airborne applications, where it can provide invisible to the naked-eye contrast of outdoor features. For a compact, lightweight Visible light spectral range option, please see the Pika L. For a higher spectral and spatial resolution version of the Pika IR-L, please see the Pika IR-L+ imager. | Fenix FENIX is optimized for the most demanding geological, law enforcement, and environmental applications. In a single continuous image, FENIX spectral camera delivers the best hyperspectral data ever seen over VNIR, NIR, and SWIR wavelengths. FENIX offers extreme ruggedness and 75% reduction in size and weight compared to previous multi-sensor systems. The excellence in technical performance and physical size has been achieved through innovative and unique ?single optics dual spectrograph? design. |
Description | Spectral range = 900 - 2300 nm Sensor spatial resolution = 320 x 256 pixels User adjustable spectral resolution: < 5 nm @ 900 nm/ <30 nm @ 2300 nm Detector type = T2SL photodiode array with CTIA ROIC, 4-stage TE cooler Number of bits = 14 bits Software interface = Labview based interface Number of spectral bands = ?* Field of view 16 degrees Working distance = 110 cm - ? Dimensions = 240 x 170 x 120 mm Weight = 5 kg Minimum Computer Requirements = 16 GB RAM, SSD drive suggested * HERA is FT spectroscopy based instrument and number of spectral bands is software selectable and independent from measurement | Spectral Range (nm) = 900 - 1700 Spectral Channels = 336 Spectral Bandwidth (nm) = 2.4 Spectral Resolution - FWHM (nm) = 5.6 Spatial Pixels = 640 Max Frame Rate (fps) = 240 f/# = 1.8 Interface = GigE Dimensions (mm) = 264 x 115 x 88 Weight, w/o lens (kg) = 2.95 | Spectral Range = 400-1000 / 400-780 (c-version) Spectral resolution (FWHM) = 5.5 nm (mean) Spectral sampling/pixel = 2.7 nm, With default binning Spectral bands = 224 / 140 (c-version), With default binning Numerical aperture = 1.7, With default lens Optics magnification = 0.80 Effective pixel size = 19.9x9.97 ?m, At fore lens image plane Effective slit width = 42 ?m, At fore lens image plane Effective slit length = 10.2 mm, At fore lens image plane SNR @ max. signal = 420 : 1 Spatial samples = 1024 Bit depth = 12 Maximum frame rate = 327 FPS full range / 514 FPS full range (c-version) Binning = 2,4,8 spectral and spatial Default: 2 spectral x 1 spatial ROI = Freely selectable multiple bands of interest. Minimum height of ROI is two 1-binned rows. Maximum frame rate is determined by the total number of rows included in the mMROI?s Pixel operability = 99.993% Image corrections = Non uniformity correction/Bad pixel replacement/Automatic Image Enhancement (AIE)/One point NUC. AIE: Unified spectral calibration + corrected smile and keystone aberrations Sensor material = CMOS Sensor cooling = Passive Full well capacity = 90 ke- Read-out modes = IWR / ITR Optics temperature = Passive Lens mount = Custom mount Fore lens FOV options = 12 deg/ 38 deg (default)/ 47 deg/ 51 deg/ 83 deg. Only the default lens is specifically designed for FX10. With other lens options, optical parameters may vary. Camera digital data output/control interface = GigE Vision, CameraLink Camera control protocols = GenICam, ASCII Power input = 12 V DC (+-10%) Power consumption = Max 4 W Connectors = Industrial Ethernet OR CameraLink 26-pin, 0.5? MDR IP = IP52 Dimensions (L x W x H) = 150 x 85 x 71 mm Mounting surface option on three sides. Mounting kit adds 24 mm distance on mounting side. Weight = 1.3 kg Storage temperature = -20 ... +50?C (non-condensing) Operating temperature = +5 ? +40?C (non-condensing) Relative humidity = 5% - 95% (non-condensing) | Spectral range = 930 - 2500 nm Spatial pixels = 384 Spectral channels = 288 Spectral sampling = 5.45 nm FOV* = 16? Pixel FOV across/along* = 0.73/0.73 mrad Bit resolution = 16 bit Noise floor = 150 e- Dynamic range = 7500 Peak SNR (at full resolution) > 1100 Max speed (at full resolution) = 400 fps Power consumption = 30 W Dimensions (l-w-h) = 38 - 12- 17.5 cm Weight = 5.7 kg Camera Interface = CameraLink *Can be doubled with FOV expander | Spectral Range (nm) = 925 - 1700 Spectral Channels = 236 Spectral Bandwidth (nm) = 3.3 Spectral Resolution - FWHM (nm) = 5.9 Spatial Pixels = 320 Max Frame Rate (fps) = 364 f/# = 1.8 Interface = GigE Dimensions (mm) = 210 x 68 x 63 Weight, w/o lens (kg) = 1.01 |