Baldur S-384 N covers the spectral range from 960-2500 nm.
All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur S-384 N is better than 1.5 pixels, yielding a very sharp camera.
HySpex Baldur S-384 N
SWIR Compare
HySpex Baldur S-384 N
Spectral Range = 960 – 2500nm
Spectral bands = 288
Max speed* = 500 fps
Spectral sampling = 5.45 nm
Spectral FWHM <2 bands
Spatial FWHM <1.3 pixels
Spatial pixels = 384
Keystone <15% of a pixel
Smile <15% of band
FOV = 16? / 40?
Bit resolution = 16 bit
Noise floor = 150 e-
Peak SNR >1100
Dynamic range = 7500
ROI* = All bands can be selected/deselected individually
External trigger options LVDS, 5V/12V/24V TTL
Dimensions (l-w-h) = 368 – 131 – 175 mm
Camera Interface = CameraLink
* Reducing the number of spectral channels with ROI will proportionally increase the max framerate
Quick Comparison
HySpex Baldur S-384 N remove | Resonon Pika XC2 remove | Resonon Pika IR+ remove | Specim FX10+ remove | Resonon Pika IR remove | Specim SWIR remove | |
---|---|---|---|---|---|---|
Name | HySpex Baldur S-384 N remove | Resonon Pika XC2 remove | Resonon Pika IR+ remove | Specim FX10+ remove | Resonon Pika IR remove | Specim SWIR remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
Rating | ||||||
Content | HySpex Baldur S-384 N Baldur S-384 N covers the spectral range from 960-2500 nm. All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur S-384 N is better than 1.5 pixels, yielding a very sharp camera. | Pika XC2 400 - 1000 nm High-Precision VNIR The Pika XC2 is a high-resolution hyperspectral camera that covers the Visible + Near-Infrared (VNIR) spectral range. The Pika XC2 has high spatial resolution, best in-class spectral resolution, and excellent imaging quality. Popular in VNIR laboratory applications. The Pika XC2 can be used in our laboratory, and outdoor, and airborne hyperspectral systems, as well as standalone or integrated into your system. | Pika IR+ 900 - 1700 nm High-Precision Infrared The Pika IR+ (formerly Pika NIR-640) is a high-performance hyperspectral camera that covers the Near-Infrared (NIR) spectral range. It has high spatial and spectral resolutions and is often used for infrared laboratory applications. The Pika IR+ can be used in our airborne, laboratory, and outdoor hyperspectral systems, as well as standalone or integrated into your system. | Specim FX10+ The Specim FX10+ is a high-speed line-scan hyperspectral camera optimized for applications requiring fast imaging. Its high resolution ensures accurate and detailed imaging at a rapid pace. Specim FX10+ operates in the visible and near-infrared (VNIR) region from 400 to 1000 nm. | Pika IR 900 - 1700 nm High-Speed Infrared The Pika IR (formerly Pika NIR-320) is a high-speed, cost-effective hyperspectral camera that covers the Near-Infrared (NIR) spectral range. It is our most popular imager for machine vision applications. The Pika IR can be used in our airborne, laboratory, and outdoor hyperspectral systems, as well as standalone or integrated into your system. | SWIR SWIR is a high-speed short-wave infrared hyperspectral camera that operates in the 1000-2500 nm range. It has 384 spatial pixels and achieves image rates of up to 400 frames per second using a CameraLink connection. To assure indoor/outdoor usage in varying conditions, it now has rugged weather-proof IP54 casing and temperature-stabilized optics but still uses less power than before, only 50W nominal. Its temperature-stabilized optics provide stability and sensitivity required in the most challenging near-infrared chemical imaging applications, from pharmaceutical quality assurance to food and agriculture analysis. The SWIR camera meets the highest requirements in the lab, industry, and field. |
Description | Spectral Range = 960 - 2500nm Spectral bands = 288 Max speed* = 500 fps Spectral sampling = 5.45 nm Spectral FWHM <2 bands Spatial FWHM <1.3 pixels Spatial pixels = 384 Keystone <15% of a pixel Smile <15% of band FOV = 16? / 40? Bit resolution = 16 bit Noise floor = 150 e- Peak SNR >1100 Dynamic range = 7500 ROI* = All bands can be selected/deselected individually External trigger options LVDS, 5V/12V/24V TTL Dimensions (l-w-h) = 368 - 131 - 175 mm Camera Interface = CameraLink * Reducing the number of spectral channels with ROI will proportionally increase the max framerate | Spectral Range (nm) = 400 - 1000 Spectral Channels = 447 Spectral Bandwidth (nm) = 1.3 Spectral Resolution - FWHM (nm) = 1.9 Spatial Pixels = 1600 Max Frame Rate (fps) = 165 f/# = 2.4 Interface = USB 3.0 Dimensions (mm) = 265 x 106 x 75 Weight, w/o lens (kg) = 2.51 | Spectral Range (nm) = 900 - 1700 Spectral Channels = 336 Spectral Bandwidth (nm) = 2.4 Spectral Resolution - FWHM (nm) = 5.6 Spatial Pixels = 640 Max Frame Rate (fps) = 240 f/# = 1.8 Interface = GigE Dimensions (mm) = 264 x 115 x 88 Weight, w/o lens (kg) = 2.95 | Spectral Range = 400-1000 nm Spectral resolution (FWHM) = 15 nm, Typical mean Spectral sampling/pixel = 6.3 nm, With default binning Spectral bands = 100, With default binning Numerical aperture = 1.7, With default lens Optics magnification = 0.80 Effective pixel size = 19.9x9.97 ?m, At fore lens image plane Effective slit width = 42 ?m, At fore lens image plane Effective slit length = 10.2 mm, At fore lens image plane SNR @ max. signal = 420 : 1 Spatial samples = 1024 Bit depth = 12 Maximum frame rate = 705 FPS full range. With 2-spectral binning (Bands: Max FPS) = 1:9900/5:6500/20:2800/35:1813/70:985 Binning = 2,4,8 spectral and spatial, Default: 2 spectral x 1 spatial ROI = Freely selectable multiple bands of interest, Minimum height of ROI is two 1-binned rows. Maximum frame rate is determined by the total number of rows included in the mMROI?s Pixel operability = 99.993% Image corrections = Non uniformity correction/Bad pixel replacement/Automatic Image Enhancement (AIE). AIE: Unified spectral calibration + corrected smile and keystone aberrations. One point NUC Sensor material = CMOS Sensor cooling = Passive Full well capacity = 90 ke- Read-out modes = IWR / ITR Optics temperature = Passive Lens mount = Custom mount Fore lens FOV options:12 deg/38 deg (default)/47 deg/51 deg/83 deg. Only the default lens is specifically designed for FX10. With other lens options, optical parameters may vary. Camera digital data output/control interface = GigE Vision Camera control protocols = GenICam, ASCII Power input = 12 V DC (+-10%) Power consumption = Max 4 W Connectors = Industrial Ethernet IP = IP52 Dimensions (L x W x H) 150 x 85 x 71 mm Mounting surface option on three sides. Mounting kit adds 24 mm distance on mounting side. Weight 1.3 kg Storage temperature = -20 ... +50?C (non-condensing) Operating temperature = +5 ? +40?C (non-condensing) Relative humidity = 5% - 95% (non-condensing) | Spectral Range (nm) = 900 - 1700 Spectral Channels = 168 Spectral Bandwidth (nm) = 4.8 Spectral Resolution - FWHM (nm) = 8.8 Spatial Pixels = 320 Max Frame Rate (fps) = 508 f/# = 1.8 Interface = GigE Dimensions (mm) = 264 x 115 x 88 Weight, w/o lens (kg) = 2.95 | Spectral range = 1000 - 2500 nm Spectral resolution (FWHM) = 12 nm (30 ?m slit) Spectral sampling / pixel = 5.6 nm F/# = F/2.0 Slit width = 30 ?m (50 or 80 ?m optional) Effective slit length = 9.2 mmRICAL CHARACTERISTICS Sensor = Cryogenically cooled MCT detector Spatial pixels = 384 Spectral bands = 288 Pixel size = 24 x 24 ?m Detector cooling = Stirling, 25 000 h MTTF Signal-to-noise ratio = 1050:1 (at max. signal level) Camera output = 16 bit CameraLink Data cable Length = 5m Camera control = USB/RS232 Frame grabber = NI-1433 Epix grabber = E4* Frame rate = 450 fps (maximum full frame) Exposure time range = 0.1 - 20 ms Power consumption = Nominal < 50 W Input voltage = 18 - 36 VNICAL CHARACTERISTICS Size (L x W x H) = Sensor 545 x 176 x 178 mm, PSU & control unit 300 x 190 x 130 mm Weight = 14 kg & approx. 5 kg Body = Anodized aluminium with mounting screwholes Lens mount = Standard C-mount Shutter = Electro-mechanicalONMENTAL CHARACTERISTICS Storage = -20... +50 ?C Operating = +5... +40 ?C non-condensing |
Leave a Reply