Assessing hyperspectral microscopy in real-time
The FireflEYE 185 brings hyperspectral imaging to microscopy, and also enables endoscopy. In life sciences the time-saving advantage of the snapshot technology (thanks to no-scanning) really makes itself known, as saving time saves patients. The camera can also monitor real-time processes, such as samples in petri dishes for example. The relay lens also allows for a lens change without camera re-calibration. And a close-up lens set allows a macroscopic scale view of a spot size of just a few mm.
For all scenarios
UAS Mapping – The FireflEYE 185 was the first-ever light-weight hyperspectral snapshot camera used for aerial mapping from a UAS. The user has a choice of lenses, enabling different fields of view for different tasks. In lab use the FireflEYE can be equipped with close-up lenses, allowing a macroscopic scale view with a spot size of only a few mm to cm. Attaching a relay lens to the FireflEYE provides for full interchangeability to Cmount lenses. Mount the camera on your microscope or endoscope without the need of an additional calibration. The latest improvements to the FireflEYE include upgrading the main sensor to a modern CMOS sensor. The 14-bit version has 2x higher signal-to-noise-ratio and 4x higher dynamic range compared to the S185 (needing 4 times longer integration times).
Cubert FIREFLEYE 185
VNIR Compare
Cubert FIREFLEYE 185
Spectral Range = 450 – 950 nm
Number of Bands = 125
FWHM = 8 nm @ 532 nm
Max Resolution = 1000 x 1000 pixel
Weight = Standard version: 490 g
Dimensions = Standard version: 200 x 67 x 60 mm
Technology = Multipoint Spectrometer
Sensor(s) = 5 MP & 2 MP
Spectral Sampling = 4 nm
Wavelength Error < 4 nm
Total Spectra / Image = 2500 & 1 M pansharpened
Total Data Points (Data Points / Cube) = 0.3 million
Data Depths = 12 Bit/ 14 Bit
Readout = Global shutter
Max Frame Rate = Standard version: 25 Hz
Integration Time = 0.1-1000 ms
Field of View (FOV) = 30?, 20?, 13?, 7?, lens selectable
Power Consumption = 7 W
Quick Comparison
Cubert FIREFLEYE 185 remove | HySpex VNIR-3000N remove | Resonon Pika IR remove | Resonon Pika IR-L remove | Hyspex SWIR-640 remove | HySpex Mjolnir VS-620 remove | |
---|---|---|---|---|---|---|
Name | Cubert FIREFLEYE 185 remove | HySpex VNIR-3000N remove | Resonon Pika IR remove | Resonon Pika IR-L remove | Hyspex SWIR-640 remove | HySpex Mjolnir VS-620 remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
Rating | ||||||
Content | Assessing hyperspectral microscopy in real-time The FireflEYE 185 brings hyperspectral imaging to microscopy, and also enables endoscopy. In life sciences the time-saving advantage of the snapshot technology (thanks to no-scanning) really makes itself known, as saving time saves patients. The camera can also monitor real-time processes, such as samples in petri dishes for example. The relay lens also allows for a lens change without camera re-calibration. And a close-up lens set allows a macroscopic scale view of a spot size of just a few mm. For all scenarios UAS Mapping - The FireflEYE 185 was the first-ever light-weight hyperspectral snapshot camera used for aerial mapping from a UAS. The user has a choice of lenses, enabling different fields of view for different tasks. In lab use the FireflEYE can be equipped with close-up lenses, allowing a macroscopic scale view with a spot size of only a few mm to cm. Attaching a relay lens to the FireflEYE provides for full interchangeability to Cmount lenses. Mount the camera on your microscope or endoscope without the need of an additional calibration. The latest improvements to the FireflEYE include upgrading the main sensor to a modern CMOS sensor. The 14-bit version has 2x higher signal-to-noise-ratio and 4x higher dynamic range compared to the S185 (needing 4 times longer integration times). | HySpex VNIR-3000 N HySpex VNIR-3000 N is developed for field, laboratory, and airborne applications. HySpex VNIR-3000 N utilizes the same spectrograph as the other classical HySpex VNIR models. With a pixel size of 3.45?m, compared to 6. 5?m for VNIR-1800, HySpex VNIR-3000 N will have less than 1.6 pixels per FWHM of the PSF spatially and less than 1.8 bands spectrally, ensuring that narrow band features will be resolved equally for all cameras. With 3000 spatial pixels, 300 bands and a noise floor of 2.4e-, HySpex VNIR-3000N will provide outstanding SNR levels in dark environments. The camera is offered with a USB connection, allowing camera operation from any computer and reducing the cost of supplementing equipment. To visualize that the camera has a wider PSF per pixel and band relative to our normal extremely sharp cameras, we have added an N for Nyquist to the model name. | Pika IR 900 - 1700 nm High-Speed Infrared The Pika IR (formerly Pika NIR-320) is a high-speed, cost-effective hyperspectral camera that covers the Near-Infrared (NIR) spectral range. It is our most popular imager for machine vision applications. The Pika IR can be used in our airborne, laboratory, and outdoor hyperspectral systems, as well as standalone or integrated into your system. | Pika IR-L 925 - 1700 nm Lightweight Infrared The Pika IR-L is a lightweight and compact Near-Infrared (925-1,700 nm) imager. The small size and mass make it well suited for airborne applications, where it can provide invisible to the naked-eye contrast of outdoor features. For a compact, lightweight Visible light spectral range option, please see the Pika L. For a higher spectral and spatial resolution version of the Pika IR-L, please see the Pika IR-L+ imager. | HySpex SWIR-640 The HySpex SWIR-640 hyperspectral camera is developed for field, laboratory, and airborne applications. HySpex SWIR-640 offers high spatial resolution by using a unique MCT sensor. The FPA is cooled to 150K using a sterling cooler, yielding low background noise, high dynamic range, and exceptional SNR levels. The camera offers an aberration-corrected optical system with high optical throughput (f/2.0), the data quality, sensitivity, and resolution is truly state of the art. A wide range of close-up lenses allows the use of the camera at working distances ranging from a few centimeters, with a spatial resolution of 32 ?m, to infinity for e.g. airborne remote sensing. | HySpex Mjolnir VS-620 For applications requiring low mass, combined with high-performance specifications and scientific grade data quality on the full VNIR-SWIR range, HySpex Mjolnir VS-620 is an ideal solution. Sharing the onboard data acquisition unit and navigation system, HySpex Mjolnir VS-620 is both space-efficient and cost-effective. The VNIR and SWIR optical axis are coaligned in the along-track direction, assuring perfect coregistration in the flight direction. In addition to the high-quality hyperspectral data cube, covering the spectral range from 400 - 2500 nm, with 490 bands, double resolution data in the VNIR range is always readily available. With smile and keystone less than 0.1 pixels for each spectral range, the merged Mjolnir VS-620 data product will have coregistration/keystone better than 0.2 pixels for the full VNIR-SWIR range. |
Description | Spectral Range = 450 - 950 nm Number of Bands = 125 FWHM = 8 nm @ 532 nm Max Resolution = 1000 x 1000 pixel Weight = Standard version: 490 g Dimensions = Standard version: 200 x 67 x 60 mm Technology = Multipoint Spectrometer Sensor(s) = 5 MP & 2 MP Spectral Sampling = 4 nm Wavelength Error < 4 nm Total Spectra / Image = 2500 & 1 M pansharpened Total Data Points (Data Points / Cube) = 0.3 million Data Depths = 12 Bit/ 14 Bit Readout = Global shutter Max Frame Rate = Standard version: 25 Hz Integration Time = 0.1-1000 ms Field of View (FOV) = 30?, 20?, 13?, 7?, lens selectable Power Consumption = 7 W | Spectral range = 400 - 1000 nm Spatial pixels = 3000 Spectral channels = 300 Spectral sampling = 2.0 nm FOV* = 16? Pixel FOV across/along* = 0.096/0.32 mrad Bit resolution = 12 bit Noise floor = 2.37 e- Dynamic range = 11000 Peak SNR (at full resolution) > 170 Max speed (at full resolution) = 117 fps Power consumption = 30 W Dimensions (l-w-h) = 39 - 9.9- 15 cm Weight = 5.0 kg Camera Interface = USB3 *Can be doubled with FOV expander | Spectral Range (nm) = 900 - 1700 Spectral Channels = 168 Spectral Bandwidth (nm) = 4.8 Spectral Resolution - FWHM (nm) = 8.8 Spatial Pixels = 320 Max Frame Rate (fps) = 508 f/# = 1.8 Interface = GigE Dimensions (mm) = 264 x 115 x 88 Weight, w/o lens (kg) = 2.95 | Spectral Range (nm) = 925 - 1700 Spectral Channels = 236 Spectral Bandwidth (nm) = 3.3 Spectral Resolution - FWHM (nm) = 5.9 Spatial Pixels = 320 Max Frame Rate (fps) = 364 f/# = 1.8 Interface = GigE Dimensions (mm) = 210 x 68 x 63 Weight, w/o lens (kg) = 1.01 | Spectral range = 960 - 2500 nm Spatial pixels = 640 Spectral channels = 360 Spectral sampling = 4.38 nm FOV* = 16? Pixel FOV across/along* = 0.44/0.44 mrad Bit resolution = 16 bit Noise floor = 80 e- Dynamic range = 7500 Peak SNR (at full resolution) > 800 Max speed (at full resolution) = 235 fps Power consumption = 10 W Dimensions (l-w-h) = 36 - 11- 15 cm Weight = 4.1 kg Camera Interface = CameraLink *Can be doubled with FOV expander |
Leave a Reply